- Certificate
- IP-COA-SL-261007
- Issued
- 7 October 2026
- Status
- released
SLU-PP-332
Small-molecule pan-ERR agonist
- 5 mg
- IdentityConfirmedMass spectrometry
- Endotoxin< 0.05 EU/mgKinetic chromogenic LAL
- SterilityNo growthMembrane filtration
- Analysed4 October 2026Batch made 3 October 2026
Full analytical results
Tests and specifications
| Test | Method | Specification | Result | Status |
|---|---|---|---|---|
| Appearance | Visual inspection | White to off-white crystalline powder | Conforms | Pass |
| Purity | HPLC with UV detection | ≥ 99.0% | 99.03% | Pass |
| Identity | ESI-MS | [M+H]+ = 291.33 ± 0.50 | 291.38 | Pass |
| Identity | ¹H NMR | Conforms to reference spectrum | Conforms | Pass |
| Related substances | HPLC, any single impurity | ≤ 0.5% | 0.08% | Pass |
| Water content | Karl Fischer titration | ≤ 2.0% | 1.06% | Pass |
| Residue on ignition | USP <281> | ≤ 0.1% | 0.043% | Pass |
| Heavy metals | ICP-MS | ≤ 10 ppm | < 5 ppm | Pass |
| Bacterial endotoxins | Kinetic chromogenic LAL | < 1.0 EU/mg | < 0.05 EU/mg | Pass |
| Sterility | Membrane filtration (USP <71>) | No growth | No growth | Pass |
| Residual solvents | Headspace GC-FID (USP <467>) | Acetonitrile ≤ 410 ppm, methanol ≤ 3000 ppm, dichloromethane ≤ 600 ppm (ICH Q3C) | Conforms | Pass |
Chromatogram
HPLC trace for this batch. One dominant peak at 4.7 minutes, 99.03% of the total peak area, largest single impurity 0.08%.
Mass spectrum
Electrospray ionisation. Expected 291.33, observed 291.38, a difference of 0.05 m/z at charge state 1. The smaller peak to its right is the sodium adduct, [M+Na]+, which electrospray produces alongside the protonated ion.
Reference data
- CAS number
- 303760-60-3
- Molecular formula
- C18H14N2O2
- Molecular weight
- 290.32 g/mol
- Modifications
- An acylhydrazone with E geometry at the carbon to nitrogen double bond: (E)-4-hydroxy-N'-(naphthalen-2-ylmethylidene)benzohydrazide.
Public reference values for the compound, not measurements on this batch. The batch measurements are in the table above.
Storage and handling
- Unopened
- 2 to 8 °C, away from light and moisture
- Long term
- −20 °C, for the stated shelf life
- Reconstituted
- 2 to 8 °C, use within 4 weeks
- In transit
- Stable at ambient temperature for up to 30 days
- Reconstitute with
- Bacteriostatic water
The vial this covers
The label on your vial carries the same batch code as this certificate, IP-SL-261003, and the QR goes to the results for it. If the code on the vial is not this one, the certificate for it is on this page under earlier batches.
Sticker shown at its printed size, 40 by 20 mm. Cap colour may vary by batch.
Release
- Batch date
- 3 October 2026
- Analysis date
- 4 October 2026
- Issue date
- 7 October 2026
- Best before
- October 2028
- Released by
- Quality review, Indigo Peptides
- Document
- Valid only in its original, unmodified form
Results are taken from the batch testing documentation for this exact batch, supplied with the finished vials and held on file by us. Every value above is for the batch named on this certificate and for no other.
Holding an older vial?
| Batch | purity | Analysed |
|---|---|---|
| IP-SL-260913 | 99.23% | 14 September 2026 |
If the code on your vial is one of these, it is an earlier batch of ours and these are its results. A result we have published is never removed and never recalculated.