Order by 3 pm and it ships the same day · Free delivery across India
Indigo PeptidesCertificate of analysis
Certificate
IP-COA-AW-261006
Issued
4 October 2026
Status
released

Acetic acid water

Sterile dilute acetic acid solution for reconstituting poorly soluble peptides

BatchIP-AW-261002This is the code printed on your vial.
Applicable strengths
  • 10 mL
101.1%HPLC with UV detectionSpecification 95.0 to 105.0% of label claim

Full analytical results

Tests and specifications

TestMethodSpecificationResultStatus
AppearanceVisual inspectionClear, colourless solution, free from visible particlesConformsPass
IdentityHPLC retention time against reference standardConforms to referenceConformsPass
AssayHPLC with UV detection95.0 to 105.0% of label claim101.1%Pass
pHPotentiometry at 25 °C4.0 to 7.05.8Pass
Particulate matterLight obscuration (USP <788>)≤ 6000 particles ≥ 10 µm per container (USP <788>)ConformsPass
Bacterial endotoxinsKinetic chromogenic LAL< 0.25 EU/mL< 0.1 EU/mLPass
SterilityMembrane filtration (USP <71>)No growthNo growthPass
Container closure integrityDye ingressNo ingressConformsPass

Reference data

Also known as
AA water, 0.6% acetic acid
CAS number
64-19-7
Molecular formula
C2H4O2
Molecular weight
60.05 g/mol
Modifications
The solute. The certificate assays its concentration in the finished solution.

Public reference values for the compound, not measurements on this batch. The batch measurements are in the table above.

Storage and handling

Unopened
Room temperature, away from light
After first withdrawal
2 to 8 °C, use within 4 weeks
In transit
Stable at ambient temperature
Do not
Freeze

The vial this covers

The label on your vial carries the same batch code as this certificate, IP-AW-261002, and the QR goes to the results for it. If the code on the vial is not this one, the certificate for it is on this page under earlier batches.

Sticker shown at its printed size, 40 by 20 mm. Cap colour may vary by batch.

Release

Batch date
2 October 2026
Analysis date
3 October 2026
Issue date
4 October 2026
Best before
October 2028
Released by
Quality review, Indigo Peptides
Document
Valid only in its original, unmodified form

Results are taken from the batch testing documentation for this exact batch, supplied with the finished vials and held on file by us. Every value above is for the batch named on this certificate and for no other.

Holding an older vial?

BatchAnalysed
IP-AW-26091112 September 2026

If the code on your vial is one of these, it is an earlier batch of ours and these are its results. A result we have published is never removed and never recalculated.